Description
1. General The specifications are applicable to Lidinglong motor models 6050-50KV outrunner brushless
2. Operating condition
Item | Specification | Condition remark | |
2-1 | Use voltage range | 0~24V DC | |
2-2 | Use temperature range | -20 ~ +80°C | No icing, no condensation, no moisture condensation, no chemical corrosion |
2-3 | Use humidity range | 40% ~ 85%RH | No moisture condensation, no chemical corrosion |
3. Measuring condition
Item | Specification | Condition remark | |
3-1 | Temperature | +5 ~ +35°C | Tested at normal temperature and humidity, if there is any doubt about the results, the test data at 20 ± 3 °C shall prevail |
3-2 | Humidity | (65±20%)RH | |
3-3 | Test voltage | 10V | DC |
3-4 | Test drive board | Motor tester | Skrc motor tester |
3-5 | Position | Axial vertically downward |
- Mechanical specification
Item | Specification | Condition remark | |
4-1 | Dimensions | Refer to the dimension drawing | Please refer to the outline drawing of the motor for details. |
4-2 | Weight | <1166g | Only for products confirmed in this specification |
4-3 | Appearance and color | Black | Visual inspection |
4-4 | Hall line definition | Black | Please refer to the outline drawing of the motor for details. |
4-5 | Motor wire length | None | Please refer to the outline drawing of the motor for details. |
4-6 | Motor shaft diameter length | Diameter 8.0mm length 40.8mm | Please refer to the outline drawing of the motor for details. |
4-7 | Motor mounting hole | 4-M4 pitch 60mm |
5. Performance and characteristic
Item | Specification | Condition remark | |
5-1 | Stator and rotor structure | 18N20P | |
5-2 | Rated voltage | 24V | DC |
5-3 | KV value | 49KV±5% | Test under DC24V voltage, use a motor tester to test |
5-4 | No-load speed | 1207±5%rpm | Test under DC24V voltage, use a motor tester to test |
5-5 | No-load voltage | 24V | Data for reference |
5-6 | No-load current | 0.55A Max | Test under DC24V voltage, use a motor tester to test |
5-7 | Rated speed | 940rpm | Data for reference |
5-8 | Rated input current | 8A | Data for reference |
5-9 | Rated output power | 200W | Data for reference |
5-10 | Rated output torque | 1.6N.M | Data for reference |
5-11 | Maximum current | 22A | Data for reference |
5-12 | Maximum torque | 5N.M | Data for reference |
5-13 | Inductance | 0.22-0.55 mH | LP-Q 1.0kHz |
5-14 | Terminal resistance | 220±5 % mΩ | |
5-15 | Three-phase resistance difference | ≤10mΩ | Three-phase internal resistance difference |
*Note: All test data are measured by our test environment and test instruments. When the test environment and test instruments change, the test results will have certain deviations. When there is any disagreement, our company’s test environment and test instruments shall prevail.
6. Simulated performance curve reference chart, analog voltage 24V
7. Precautions for use
7-1:The motor should be carefully and gently placed during transportation and handling to avoid damage to the motor body and performance caused by collision and knocking.
7-2: The motor should be stored at room temperature and humidity (25 ℃, 65% RH) ventilation environment, to prevent moisture, and chemical corrosion (Note: more than 6 months, the internal spindle will oxidation rust for normal phenomenon.
In the case that it does not affect the performance, it is still regarded as qualified products)
7-3: Don’t block the shaft often after the power is connected. Welding should be done within 5 seconds to avoid damaging the terminals or wires.
8. Product packaging standards
8-1: The motor is labeled with a nameplate on the outside, indicating the name of the motor and the relevant number and other information;
8-2: neatly arranged trays of products are stacked in the packaging box;
8-3: The total number of each box:
8-4: Seal the outer box with sealing tape: and paste the relevant information on the outer box as requested by the customer for shipment:
9. Remark
9-1: This specification is for engineering sample confirmation. Large-scale production will be performed according to this sample confirmation standard. After the sample confirmation, please make sure to sign and return it.
9-2: If the sample is not signed and returned within 3 working days after the sample is confirmed, the sample will be confirmed by default when the order is placed by the user.
Reviews
There are no reviews yet.